Login

NEW ELTEK 241119.105 FLATPACK2 48/3000 High ...

Author: Geoff

Jul. 15, 2024

59

0

NEW ELTEK .105 FLATPACK2 48/ High ...

New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details.

NEW ELTEK .105 FLATPACK2 48/ High ...

New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details.

See all condition definitions

opens in a new window or tab

Eltek Rectifier Output 48V W Flatpack 2 48/he ...

Short Description:

 

Since setting the new standard for rectifier efficiency, the Flatpack2 HE family is now available in a variety of voltages and power ratings, all with superior efficiency up to 96.5%.

With more than 4 billion in-field operating hours and a proven cumulative field MTBF of more than 1,9 million hours, Flatpack 2 HE is the only HE (High Efficiency) rectifier with a proven track record.

The line of systems available for Flatpack2 HE 48V rectifiers spans from 8kW 2U racks with complete distribution to multi-cabinet systems in multi MW installations.

Applications

Telecom - Mobile / Wireless
&#;radio Base Stations/ Cell Sites
&#;lte / 4g / Wimax
&#;mobile Switching Center (msc)
&#;microwave
&#;broadband Telecom - Fixed
&#;central Office
&#;telephony Servers / Switches
&#;fiber Optics
&#;microwave
&#;broadband
&#;datacenters

Power Utilities
&#;scada

Key Features
&#;proven Reliability
&#;high Efficiency (he)
&#;power Dense, Up To 33 W/inch3
&#;wide Temperature Range
&#;application Flexibility 2kw
&#;global Compliance (ce, Ul)
&#;patented He Technology

Specification

Model 48V / W HE 48V / W HE Part number .105 .105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC 176 - 277 VAC Voltage (range) 85 - 300 VAC / 85 - 275 VDC 85 - 305 VAC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz 45 - 66 Hz Current (maximum) @ nominal input, full load 11.6 ARMS 19.2 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC Fuse in both lines Varistor for transient protectionDisconnect above 305 VAC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC 43.5 - 583) VDC Power (maximum) W W Power @ 85 VAC 850 W W Current (maximum) @ nominal input, full load 41.7 A 62.5 A Ripple, 30MHz bandwidth < 100 mVpp < 150 mVpp Psophometric noise < 2 mVRMS < 2 mVRMS Static Voltage regulation ±0.5% for 10 - 100% load Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25°Cfull load @ Tambient = 40°C < 20 dBA< 56 dBA < 40 dBA< 58 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 °C) >300 000 (@ Tambient : 25 °C) Operating temperature -40 to +75°C (-40 to +167°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55°C (131°F), W @ 75°C (167°F) >55°C4) (131°F), W @ 75°C (167°F)4) Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13") / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN -1:+A11:+A1:+A12:+A2:, UL -1:, CSA C22.2 No.-1-07:, IEC -1: EMC EN -6-1:, -6-2:, - 6-3: + A1:, - 6-4:, EN -3-2: ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR CORE Marine DNVGL-CG-) -  Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU /863 (RoHS) & /19/EU (WEEE)Normal operating conditions as per IEC -5-3: clause 4.2. Other operating conditions as per IEC -5-3: clause 4.3, must be advised power derating, maximum W @ 230Vac 16 2/3 Hzonly valid for part number .105M 57.6V for HW revision &#; 5 from HW revision 6: shutdown at 95°C with de-rating to ~W

Hotsale Modules

1

Rectifier module

Emerson /Vertiv

R48-A

2

Rectifier module

Emerson /Vertiv

R48-A3

3

Rectifier module

Emerson /Vertiv

R48-U

4

Rectifier module

Emerson /Vertiv

R48-e3

5

Rectifier module

Emerson /Vertiv

R48-e

6

Rectifier module

Emerson /Vertiv

R48-A

7

Rectifier module

Huawi

RN1

8

Rectifier module

Huawi

RG1

9

Rectifier module

Eltek

Flatpack2 48/ HE
.105

10

Rectifier module

Eltek

Flatpack2 48/ HE
.105

11

Rectifier module

Eltek

Flatpack2 48/ HE
.105

12

Rectifier module

Eaton

APR24-3G

Further reading:
Ftta Fiber Optic Cable 5.0mm Patch Cord with IP67 ...
Single-Mode SC APC Fiber Field Assembly Fast Connector
The Best Places to Buy China Fiber optic splice enclosures Exporter Online and In-Store
Exploring the Huawei Mini SC Connector Benefits
Top Custom Fiber Optic Power Loss Testers Exporters
Exploring 400G SR4: Trends and Insights 2024
Adss Cable Exports from China

See all condition definitions

opens in a new window or tab

Eltek Rectifier Output 48V W Flatpack 2 48/he ...

Short Description:

 

Since setting the new standard for rectifier efficiency, the Flatpack2 HE family is now available in a variety of voltages and power ratings, all with superior efficiency up to 96.5%.

With more than 4 billion in-field operating hours and a proven cumulative field MTBF of more than 1,9 million hours, Flatpack 2 HE is the only HE (High Efficiency) rectifier with a proven track record.

The line of systems available for Flatpack2 HE 48V rectifiers spans from 8kW 2U racks with complete distribution to multi-cabinet systems in multi MW installations.

Applications

Telecom - Mobile / Wireless
&#;radio Base Stations/ Cell Sites
&#;lte / 4g / Wimax
&#;mobile Switching Center (msc)
&#;microwave
&#;broadband Telecom - Fixed
&#;central Office
&#;telephony Servers / Switches
&#;fiber Optics
&#;microwave
&#;broadband
&#;datacenters

Power Utilities
&#;scada

Key Features
&#;proven Reliability
&#;high Efficiency (he)
&#;power Dense, Up To 33 W/inch3
&#;wide Temperature Range
&#;application Flexibility 2kw
&#;global Compliance (ce, Ul)
&#;patented He Technology

Specification

Model 48V / W HE 48V / W HE Part number .105 .105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC 176 - 277 VAC Voltage (range) 85 - 300 VAC / 85 - 275 VDC 85 - 305 VAC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz 45 - 66 Hz Current (maximum) @ nominal input, full load 11.6 ARMS 19.2 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC Fuse in both lines Varistor for transient protectionDisconnect above 305 VAC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC 43.5 - 583) VDC Power (maximum) W W Power @ 85 VAC 850 W W Current (maximum) @ nominal input, full load 41.7 A 62.5 A Ripple, 30MHz bandwidth < 100 mVpp < 150 mVpp Psophometric noise < 2 mVRMS < 2 mVRMS Static Voltage regulation ±0.5% for 10 - 100% load Dynamic Voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25°Cfull load @ Tambient = 40°C < 20 dBA< 56 dBA < 40 dBA< 58 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 °C) >300 000 (@ Tambient : 25 °C) Operating temperature -40 to +75°C (-40 to +167°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55°C (131°F), W @ 75°C (167°F) >55°C4) (131°F), W @ 75°C (167°F)4) Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13") / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN -1:+A11:+A1:+A12:+A2:, UL -1:, CSA C22.2 No.-1-07:, IEC -1: EMC EN -6-1:, -6-2:, - 6-3: + A1:, - 6-4:, EN -3-2: ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR CORE Marine DNVGL-CG-) -  Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU /863 (RoHS) & /19/EU (WEEE)Normal operating conditions as per IEC -5-3: clause 4.2. Other operating conditions as per IEC -5-3: clause 4.3, must be advised power derating, maximum W @ 230Vac 16 2/3 Hzonly valid for part number .105M 57.6V for HW revision &#; 5 from HW revision 6: shutdown at 95°C with de-rating to ~W

Hotsale Modules

1

Rectifier module

Emerson /Vertiv

R48-A

2

Rectifier module

Emerson /Vertiv

R48-A3

3

Rectifier module

Emerson /Vertiv

R48-U

4

Rectifier module

Emerson /Vertiv

R48-e3

5

Rectifier module

Emerson /Vertiv

R48-e

6

Rectifier module

Emerson /Vertiv

The company is the world’s best vertiv 6 kva ups supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

R48-A

7

Rectifier module

Huawi

RN1

8

Rectifier module

Huawi

RG1

9

Rectifier module

Eltek

Flatpack2 48/ HE
.105

10

Rectifier module

Eltek

Flatpack2 48/ HE
.105

11

Rectifier module

Eltek

Flatpack2 48/ HE
.105

12

Rectifier module

Eaton

APR24-3G

If you are looking for more details, kindly visit huawei outdoor cabinet.


 
Further reading:
Fiber Protection Sleeve | 60mm | 45mm | 40mm Supplier
Why Choose Custom Fiber Optic Cable Drums?
What are the key benefits of GJFXTKV products?
Unlock High-Speed Connectivity with Corning OptiTap Patch Cords
What to Know About Multi Service Terminal Closure?
How Does Multi Service Terminal Closure Impact User Experience?
MPO Patch Panel vs. Traditional Patch Panels: Key Differences Explained

Comments

0

0/2000

Related Articles

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)

Join Us